Welcome visitor you can login or create an account.
.
-
ALL MODELS INCLUDE:
1 cm2 Rubber Tip - Replacement (FDK/RT) and Accuracy Verification Hook - Replacement (FDK/HK)
Add a NIST Traceable Accuracy Verification Certificate?
-
POUND - GRAM MODELS | |||||||
MODEL | CAPACITY / GRADUATION | ||||||
FPK 5 | 5 lbf x 0.05 lbf | 2500 gf x 25 gf | |||||
FPK 10 | 10 lbf x 0.10 lbf | 5 kgf x 50 gf | |||||
FPK 20 | 20 lbf x 0.25 lbf | 10 kgf x 100 gf | |||||
FPK 40 | 40 lbf x 0.50 lbf | 20 kgf x 200 gf | |||||
FPK 60 | 60 lbf x 0.50 lbf | 30 kgf x 250 gf |
* FPK 10/FPN 50 - For tissue over bone and more sensitive areas. | ||||
** FPK 20/FPN 100 - Most popular for pain threshold trigger points. | ||||
*** FPK 40/FPN 200 - Popular with dual use for pain threshold and pain tolerance. | ||||
**** FPK 60/FPN 300 - For veterinary use on large animals, e.g., horses. | ||||
Included: Force Gage, rubber tip, verification hook, manual and case |
NEWTON - GRAM MODELS | |||||||
MODEL | CAPACITY / GRADUATION | ||||||
FPN 20 | 20 N x 0.25 N | 2500 gf x 25 gf | |||||
FPN 50 | 50 N x 0.5 N | 5 kgf x 50 gf | |||||
FPN 100 | 100 N x 1 N | 10 kgf x 100 gf | |||||
FPN 200 | 200 N x 2 N | 20 kgf x 200 gf | |||||
FPN 300 | 300 N x 2.5 N | 30 kgf x 250 gf |
* FPK 10/FPN 50 - For tissue over bone and more sensitive areas. |
** FPK 20/FPN 100 - Most popular for pain threshold trigger points. |
*** FPK 40/FPN 200 - Popular with dual use for pain threshold and pain tolerance. |
**** FPK 60/FPN 300 - For veterinary use on large animals, e.g., horses. |
Included: Force Gage, rubber tip, verification hook, manual and case |
The Wagner Pain Test™ Model FPK Algometeris the worldwide preferred threshold and pain tolerance gage of physicians, chiropractors, physical therapists and other health practitioners. Pressure algometry has been proven a valid measure of localized pain in muscle, joints, tendons, ligaments and bones.
The FPK proves to the patient, health practitioner or insurance companies, the benefits of the medication, physiotherapy or applied manipulation.
As treatment progresses, the FPK quantifies improvements or setbacks. Pain threshold measurements provide unique information not obtainable by any other method. This documentation can be used for clinical and research purposes. For patients, the objective measurements give reassurance, confirming their improvement.
Pain Threshold
The minimum pressure which induces pain in tender and trigger points of tissue. The FPKquantitatively assesses the tenderness over hypersensitive areas. The FPK lower capacities are used for pain threshold testing. The lower range is appropriate for determining the minimum pressure that triggers pain at the point of interest.
Pain Tolerance
The point where a painful pressure stimulus can no longer be tolerated. The FPK, assesses pain-pressure sensitivity of muscle for maximum tolerated pressure. The higher capacities are used for pain tolerance testing. The wider range is necessary for comparative tests between a normal sensitivity control point and the area of interest.
Pressure Pad - An optional accessory used alternately or in addition to the 1 cm² rubber tip. The patient is active, pressing the foot, leg or arm against the pressure pad toevaluate pain threshold or pain tolerance.
CONSTRUCTION
OPERATION
|
ACCESSORIES
ACCURACY
WEIGHT & DIMENSIONS
|
RELATED PRODUCTS: |
WAGNER INSTRUMENTS.
Post Office Box 1217, Greenwich, CT 06836-1217 USA
Phone: + 203-698-9681 or 800-345-4188 (U.S. & Canada)
Fax: + 203-698-9696 or 800-443-4149 (U.S. & Canada)